1. Initial situation
In order to be able to use a telephony DECT handset M65 / M85 with Festnetz+ , it must be coupled once with a telephony DECT transmitter. These instructions describe both the registration process and any deregistration process that may be used. The so-called IPEI number is essential for this registration process.
2. Find the SBX inventory number and IPEI number
To find the Seabix inventory number or the IPEI number, do the following:
- Open the back of the handset
- Remove the battery
- Below this is the Seabix inventory number and the IPEI number as a barcode
To find the IPEI number via the device menu without switching off the device, proceed as follows:
- M65 / M85. Press the menu button
- Then select the settings using the gear button, confirm by clicking on the center of the round navigation button
- Click the lower edge of the navigation button until you get to the menu item Status, then confirm again in the middle
- Navigate again down to the point IPEI address (e.g. 01: AE: F9: EF: DA)
2. Register the handset
- M65 / M85. Press the menu button
- Then select the settings via the registration menu and confirm by clicking on the center of the round navigation button
- Press the OK button in the center of the navigation button to open the "Connection" menu. The blue background of a line indicates that this option is currently selected. "Register" must be selected to register the handset at the base station
- Push on M65 / M85. In the next step, select the top empty line and confirm with the navigation key
- Enter the code provided by Seabix support as the access code and confirm with the navigation key
- The last step you see is the following, the device is now registered
3. Unregister the handset
- M65 / M85. Press the menu button
- Then select the settings via the registration menu and confirm by clicking on the center of the round navigation button
- In the next menu, select Registr. and confirm with the navigation key
- Enter the code provided by Seabix Support and confirm with the navigation key ^.
- Confirm the new query
4. Reset the handset to factory settings
- M65 / M85. Press the menu button
- Select the gear and confirm with the navigation key
- Navigate to the menu item on Settings. reset and confirm with the navigation key
- Confirm the query with Yes
- Enter the code provided by Seabix Support and confirm again